Skip to main content
Chefs Studio Journal

Kitchen energy costs: what to track each week

On behalf of Ian McAndrew

In Brief: Put kitchen energy costs on the same weekly sheet as food cost and labour. Record how much gas and electricity was used, what that usage cost and how many covers you served. Those figures can help you spot where an oven is warming up too early or a piece of kit needs a closer look.

Start by checking what the meter covers.

Read the same meter on the same day and at roughly the same time each week. A photo of the display can make the reading easier to check later. If you have a supplier portal or building report with reliable readings, use the same seven-day window each time.

A kitchen submeter records the equipment connected to it. Check what it covers before labelling the figure kitchen-only. If you have one metre for the whole building, record the whole-site use. It may include the dining room, bar, heating and hot water as well as the kitchen.

Turn the meter readings into a weekly usage cost.

  1. Electricity. Subtract the previous cumulative reading from the latest one to get kilowatt-hours (kWh) used.
  2. Gas. If the meter records cubic metres or cubic feet, convert the change to kWh using your supplier’s billing method. Use the kWh figure directly if your supplier already provides it for the week.
  3. Cost. Multiply each fuel’s kWh by its rate and add the results. If you have different rates by time of day, use the readings for each rate or ask the supplier for a breakdown.

Keep this figure labelled as a usage cost. A full bill can also include standing charges, VAT and other charges. Use the invoice to check the full amount and note when a unit rate changes. Two weeks can use the same number of kWh and cost different amounts.

Compare energy use and cost per cover.

Use cover counts for the same period as the meter readings. Divide kWh by covers to see energy use per guest, and divide the usage cost by covers to see what that use cost is per guest. Keep the total kWh and cover count alongside both figures. If you served no covers that week, record the totals only.

Suppose you used 600 kWh of electricity at an illustrative rate of 25p per kWh. That’s £150 in usage charges. At 300 covers, it works out at 2 kWh and 50p per cover. At 240 covers, the same usage and cost come to 2.5 kWh and about 63p per cover.

The quieter week looks dearer per guest because the cost is spread across fewer covers. Refrigeration and other equipment can keep using energy between services. If total kWh rises, look at changes in opening hours, prep batches, equipment use or building heating before drawing a conclusion.

Review start-up and close-down in the kitchen.

Take one piece of cooking kit and check when it needs to be ready. Write its warm-up time on the opening sheet and schedule the start around the first job, following the manufacturer’s instructions. Use the close-down check to confirm which cooking equipment can be switched off safely and who is responsible.

Keep required extraction and ventilation running as specified for your equipment and site. Some systems need to run after cooking finishes, especially where solid fuel is still cooling. Check with a competent engineer before changing extraction timings or controls.

Keep refrigeration running where it’s needed to store food safely. Check whether doors close properly, seals are sound and stock is easy to find. Follow your food safety procedures for cooling and storage. Log recurring temperature problems and arrange a check rather than waiting for an energy bill to confirm a fault.

Check what changed before replacing equipment.

If use stays high after a change to the opening routine, compare similar trading weeks. Check whether refrigeration, hot water or heating are on the same meter, and look for changes in the number of services or batches made. If your supplier can show the use-by time of day, compare it with when the kitchen was open and when prep took place.

If one appliance still looks costly to run, ask for a service check or more specific readings before pricing a replacement. A weekly total gives you a reason to investigate. Appliance-level measurements give you stronger evidence for a purchase decision.

What to put on the weekly sheet

  • Dates, metres and what it covers
  • Electricity and gas used in kWh
  • Unit rates and weekly usage cost
  • Covers, kWh per cover and usage cost per cover
  • Changes to opening hours or equipment, and one action to check next week

Bring the sheet to the same conversation as food cost and labour. For a format for that meeting, see Chefs Studio’s weekly kitchen review. The wider pressures on the bill are covered in UK Restaurant Cost Crisis: Strategies for Survival, alongside practical checks in Chefs Studio’s guide to common kitchen cost leaks.

Frequently asked questions

Is energy a kitchen cost or an overhead?

Your accounts may record it as an overhead. It’s still worth tracking the energy the kitchen can influence through how it uses and maintains equipment.

Can I track kitchen energy without a separate meter?

Use the building’s readings to track the whole-site trend. Record what the meter includes and use equipment schedules or more specific measurements to investigate where the energy went.

What is a good energy cost per cover?

Use your own comparable weeks as a starting point. Opening hours, equipment, weather, the mix of services and tariffs can all affect the figure. Read it alongside kWh, total cost and covers.

Sources

Written by

Shaun Smith-Roberts

Chef, publisher and digital strategist, bringing professional kitchen experience together with food media, editorial development and practical digital thinking.

Read more about Shaun →

Subscribe to our list